Peltier Cooler Model 20001/018/018M

Peltier cooler model 20001/018/018M is a member of Ferrotec’s family of Telecom-Grade modules. The 20001/018/018M peltier cooler is a single-stage, 18-couple, 1.8-amp module. The 'M' code indicates that this standard thermoelectric cooler features a solderable, metalized ceramic substrate on both hot and cold side external surfaces

 

20001/018/018M — Mechanical Characteristics

Base W (mm) 6.1
Base L (mm) 7.6
Top W (mm) 6.1
Top L (mm) 6.1
Height (mm) 1.65

Performance Values

Values calculated at 50°C. I Max 1.8 ΔT Max 80.0
  V Max 2.7 Qc Max 2.6


Standard Performance Curves

Custom Options

Ferrotec can also customize a Telecom-Grade Module for you based on the 20001/018/018M.
Note: minimum quantity custom order limitations apply.

About Ferrotec’s Telecom-Grade Module Family

Ferrotec's telecom-grade peltier coolers are tested and proven to meet the demanding requirements of Telcordia testing and telecommunications applications. In addition to the standard modules listed, these telecom-grade solutions can be optimized to meet specialized design requirements.

Ambient Temperature °C Step 1
Input modeling variables

Step 2
Click “Recalculate”
Thermal Resistance (Heat Sink) °C / Watt
Number of Modules
Starting dT °C

20001/018/018M — Performance Curves

Note: Curves shown are calculated on a 'per module' basis.

Ordering Information

"*" indicates required fields

Section 1: Contact Information

* Indicates a required field

Please specify the peltier cooler or thermal solution that you are interested in, including part numbers and any special requirements. A brief description of your application is also helpful.
MM slash DD slash YYYY